AGAP |
|
|
|
| |

|
Pumps |
Various according to pump model
- please contact our technical office for details |
|
Cistern |
Polypropylene |
|
Valve |
Brass with Plastic Float |
|
Base |
Powder Coated Mild Steel |
|
Fittings |
Brass |
| |
|
|
Idromat
|
Housing Nylon
Membrane Nitrile
Sensor Brass |
|
Construction |
|
18 or 68 Ltr tank with air-gap supplying water to one of our pumps
controlled by our
Idromat regulation device
equipped with flow and pressure sensor connected to an electronic system all
mounted on a base.
|
|
Applications |
• For non-domestic quality water.
• To prevent backflow contamination of mains water.
• Whilst maintaining flow and pressure. |
|
Operating conditions |
BT61E,
BTm61E,
BT70E,
BTm70ELiquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Continuous duty.
MXH203E,
MXHm203E,
MXH204E, MXHm204E,
MXH205E, MXHm205E,
Liquid temperature from - 15 °C to + 110 °C.
Ambient temperature up to 40 °C.
Maximum permissible pressure in the pump casing: 10 bar.
Continuous duty. |
|
Motor |
Various depending on pump selection
See Pump specificationsBT61E,
BTm61E,
BT70E,
BTm70E
MXH203E,
MXHm203E,
MXH204E, MXHm204E,
MXH205E, MXHm205E,
|
|
Special Systems |
|
In addition to the standard range AGAP systems shown we can also provide special
packages to specification, incorporating other pumps or booster set packages
from our production. Units are complete with control systems and one-piece or
modular storage tanks to current legislation.
Please contact our technical sales office for further details. |
|
Warranty |
|
One year (as per our standard terms and conditions of sale) |
|
| |
Performance Data |
|
| |
| 3Phase |
230 |
400 |
1Phase |
230 |
|
Q |
|
|
|
|
|
|
|
|
|
|
|
| |
A |
A |
|
A |
kW |
m3/hr |
0.38 |
0.48 |
0.6 |
0.75 |
1 |
1.2 |
1.5 |
1.89 |
2.4 |
3 |
3.6 |
|
BT61E |
1.9 |
1.1 |
BTm61E |
2.5 |
0.33 |
H(m) |
38 |
36 |
34 |
31 |
28 |
24 |
19 |
12 |
5 |
|
|
| BT70E |
3.7 |
2.2 |
BTm70E |
6 |
0.75 |
|
59 |
57 |
55 |
51 |
48 |
43 |
38 |
30 |
22 |
10 |
|
|
| |
| 3Phase |
230 |
400 |
1Phase |
230 |
P1 |
P2 |
Q |
|
|
|
|
|
|
|
|
|
| |
A |
A |
|
A |
kW |
kW |
m3/hr |
0 |
1 |
1.5 |
2 |
2.5 |
3 |
3.5 |
4 |
4.25 |
|
MXH203E |
2.4 |
1.4 |
MXHm203E |
3 |
0.65 |
0.6 |
H(m) |
33 |
31 |
29 |
27 |
24 |
21 |
18 |
14 |
12 |
|
MXH204E |
2.8 |
1.6 |
MXHm204E |
4.2 |
0.9 |
0.75 |
45 |
42 |
40 |
37 |
34 |
30 |
25 |
21 |
18 |
|
MXH205E |
3.5 |
2 |
MXHm205E |
5.4 |
1.2 |
1 |
57 |
53 |
50 |
47 |
43 |
38 |
32 |
26 |
23 |
|
|
| |
Installation Data
All electrical connections should be made as per fig.1. DO NOT SWITCH ON
POWER SUPPLY UNTIL INSTALLATION PIPE-WORK IS MADE AND CISTERN IS FULL OF WATER.
Fig.2 refers
|
A |
Water outlet
1" BSPm |
|
B |
Cistern Water
Supply |
|
C |
Warning Pipe -
22mm compression. Note the purpose of this connection is to warn of a
potential cistern overflow condition. We therefore advise that the
pipe-work from the overflow should be located so as to visually alert
personnel should overflow occur. |
|
D |
Optional wall
mount brackets. We advise the brackets be fixed to the wall with 6mm
wall bolts. Mark holes as per template. The AGAP system is then attached
to the brackets with 4 x M6 bolts via the holes and hank bushes
provided. Wall mount brackets are only available for BT61EAGAP118 and
BT61EAGAP318 systems |
IMPORTANT - The main weir E is
provided to meet with the type AB air gap requirements. It is important that
this overflow is never restricted. It is also important to consider the
implications of water spilling through the weir/s - keep away from electrical
installations or other sensitive areas
IDROMAT OPERATION - The Idromat flow and pressure controller is fitted to
operate the pump automatically on demand. Once installation is complete, switch
on the power supply. Assuming the discharge line is closed the pump will run for
a short period to fill the system. Open the discharge line slowly to establish
flow and release air. If flow is not quickly established depress the reset
button F for a few seconds, if still no flow is present you may need to prime
the pump (see pump instructions). Remove plug G, release air, reconnect the
power and repeat above procedure.
Note: The Idromat will provide dry running
protection should the cistern empty. Do not restart the Idromat until the
cistern is full. You may need to press the reset button F.
System Status
H Power On (Green Light) - Discharge line
closed, pump idle, system pressurised.
I On (Yellow Light) - Discharge line open, pump running
J Failure (Red Light) - If no flow within 8 secs following start-up,
Idromat will recognise lack of water or
closed discharge and stop pump. Reset F may be required
NOTES - For cold water use only. We advise
the installation of a throttling valve after the Idromat discharge
to facilitate control. It is important that the outgoing flow from the pump does
not exceed the incoming flow
to the cistern.
|
|
| |
Electrical Connection (fig.1)
Single Phase Supply via fused spur (by other) to
Idromat controller. (See instruction
manual)IF IN DOUBT CONSULT A QUALIFIED
ELECTRICIAN
Three phase systems must be used in conjunction with our control box. The
Idromat controller should only be connected to a 230V single phase supply. Max.
FLC for Idromat is 10A, Max starting Current is 25A
|
|
| |
 |
|
| |
 |
|
| |
 |
|
| |
DIMENSIONS |
|
| |
BT61EAGAP118 and BT61EAGAP318 |
|
| |
 |
|
| |
BT70EAGAP168 and BT70EAGAP368 |
|
| |
 |
|
| |
MXH203EAGAP168 and MXH203EAGAP368
MXH204EAGAP168 and MXH204EAGAP368
MXH205EAGAP168 and MXH205EAGAP368 |
|
| |
 |
|
| |
Special Systems |
|
| |
 |
|
| |
|
|
| |
|
|
|
|
|
 |
 |
|