A |
Self-Priming Centrifugal Pumps
with open impeller |
pdf |
|
| |


|
Construction |
|
Close-coupled centrifugal pumps with open impeller.
The built-in backflow preventer avoids reverse siphoning when the pump is
stopped and assures automatic re-priming at the next start.
The pump re-primes itself even if partially filled with liquid and with
completely empty suction pipe. |
|
Applications |
For clean or slightly dirty water, also with solids up to 10 mm
grain size for A 50-125 and
15 mm for A 65-150.
For draining a basin or a sump.
For irrigation.
For civil and industrial applications. |
|
Operating conditions |
Liquid temperature from -10 °C to +90 °C.
Room temperature up to 40 °C.
Maximum permissible working pressure up to 10 bar.
Continuous duty. |
|
Motor |
2-pole induction motor, 50 Hz (n = 2900 1/min).
A : three-phase 230/400 V ± 10%.
AM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54
Constructed in accordance with IEC 34. |
|
Special features on request |
Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Protection IP 55.
Special mechanical seal.
Higher or lower liquid or ambient temperatures.
Construction with bearing bracket. |
|
Warranty |
|
One year (as per our general sale conditions). |