GMC, GMV Submersible Sewage and Drainage Pumps

pdf

 
 

 

Construction  
Close coupled electric submersible pumps.
GMC: with single-channel impeller.
GMV: with free-flow (vortex) impeller.
Double mechanical shaft seal with interposed oil chamber, to protect against dry-running.
Applications
For domestic or industrial waste water, dirty water with solids up to 45 mm grain size, for liquids which are compatible with the pump materials.
Operating conditions
Liquid temperature up to 35 °C.
pH value: 6-11.
Maximum immersion depth: 10 m
(with suitable cable length).
Continuous duty (with submerged motor).
Motor
2-pole induction, 50 Hz (n = 2900 rpm).
GMC, GMV:
three-phase 230 V ± 10%; three-phase 400 V ± 10%;
2 built-in thermal protectors to be connected to a control box.
Cable: 4x1,5 mm2+ 2x0,5 mm2, length 10 m.
GMCM, GMVM: single-phase 230 V ± 10%.
With float switch,
built-in thermal protector and built-in capacitor.
Cable: H07RN-F, 3x1,5 mm2, length 10 m, with plug (CEI - UNEL 47166).
Insulation class F.
Protection IP X8.
Triple impregnation, humidity-proof winding.
Constructed in accordance with: EN 60 335-2-41.
Special features on request
Other voltages.
Frequency 60 Hz (as per 60 Hz data sheet).
Warranty
One year (as per our general sale conditions).
   
 