NC3    
 
   
  Construction  
Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Brass or cast iron unions on request.
Materials NC3 ..40-50-60 NC3 ...70-80-120
Pump casing Cast iron Cast iron
Impeller Composite Composite
Shaft Stainless steel Ceramic
Applications
For clean liquids, without abrasives, which are non-aggressive for the pump materials.
Civil and industrial heaty systems.
Motor
2-pole induction motor, 50 Hz.
Three adjustable speeds.
NC3: single-phase 230 V.
Insulation class H.
Protection IP 44.
Operating conditions
Liquid temperature from +5 °C to +110 °C (from -10 °C to +110 °C for NC3 ..-70 and NC3 ..-80).
Ambient temperature up to 40 °C.
Sound pressure ≤ 43 dB (A).
Maximum glycol quantity: 50% (Mixture with more than 20% glycol content require re-checking of the pumping data).
Maximum permissible working pressure 10 bar.

Type

Minimum suction pressure: bar

Temperature
50°C 80°C 110°C
NC3 ..-40,50,60 0,05 0,4 1,1
NC3 ..-70 0,05 0,4 1,1
NC3 ..-80,120 0,05 0,4 1,2

 

Warranty
One year (as per our general sales conditions).
 

 
  Characteristic Curves