IDROMAT Electronic regulator for pumps  
 
 

Construction  
Regulation device equipped with flow and pressure sensor connected to an electronic system.
Inlet and delivery connection ports of the same diameter (G1).
Built-in check valve.
Pressure gauge 0-10 bar for IDROMAT 2.
Applications
Automatic control of pumps for water supply and increase of network pressure.
Control of starting/stopping of the pump when utilization points are opened/closed.
For protection of the pump:
– against dry running;
– against the risk of operation without water at the inlet (caused by a lack of water inflow in the inlet pipe under positive suction head, by a non-immersed suction pipe, by excessive suction lift or by air entering the suction pipe);
– against operation with closed connection ports.
Operating conditions

For pumps with delivery up to 10 m3/h.
Maximum working pressure: 10 bar.
Liquid temperature up to 60 °C.
Mains voltage: 220 V - 250 V, single-phase.
Frequency: 50 - 60 Hz.
Protection: IP 55 (IP 65 for IDROMAT 2).
Current values:
25A max at start-up;
10A during operation.